Skip To Content

Mass Flow Controllers & Meters

Mass flow control technology. Unsurpassed process precision.
To truly control any process, you must precisely measure what is happening — in the feedline, in the chamber, at every point — then use that information in real time to keep the process precisely on-target and productive.

As the global leader in precision fluid measurement and control, mass flow meter manufacturer Brooks Instrument continues to drive innovation in thermal mass flow and Coriolis flow meter and control technology. We are using new applications of digital technology to improve thermal mass flow sensors, mass flow meter designs and precision mass flow controller performance.

As industry leaders, we continually launch new products and enhance our existing portfolio, including proven elastomer sealed, metal sealed, high temperature and Coriolis mass meters and controllers.
Our goal: to unlock new levels of thermal mass flow measurement precision, responsiveness, accuracy and repeatability.

Mass flow meters and controllers:
Why precision matters.

For the industries that use mass flow fluid delivery — bioprocessing, semiconductors, thin film, chemicals and more — productivity, efficiency and profitability are all impacted by the reliability and repeatability of the process data generated by mass flow meters and the performance of fluid mass flow controllers.

Precise process control is achieved through the combination of ultra-stable, highly accurate mass flow meter sensors, fast-responding flow control valves and powerful digital electronics.

Key reasons why our mass flow controllers are the most widely used worldwide include:

  • Industry-best range of digital mass flow meters and other products to meet widest application needs
  • MultiFlo™ technology allows one device to change gas types and ranges without removing the device from the system and improving actual process gas accuracy. MultiFlo™ is offered for use with thermal mass flow controllers or mass flow meters
  • Complete product range includes both elastomer-sealed and metal-sealed options for thermal mass flow sensors and Coriolis mass flow sensors
  • Ultra high-purity mass flow meters and mass flow sensors engineered to satisfy thin film, semiconductor and other high-tech industry requirements

Key Applications

  • Heat treating, cutting and other thermal processes for mass flow sensors
  • Semiconductor and LED production tools
  • Thin film deposition systems
  • Biopharmaceutical bioreactors
  • Petrochemical and chemical gas and liquid pilot plants
  • Purge gas, process analysis and analytical flow measurement
Brooks GF100 cutaway
GF125 - Mass Flow Controller
  • Widest flow and pressure ranges
  • Long-term stability delivers sustained value
  • Includes products approved for hazardous areas
  • Hose down/wash down device enclosures
{18886FAC-2FF5-450F-8969-7D17F1954F23}
Fluid Type
Gas
{FF1F572E-D25F-41B7-8A12-E6D0153C9FBC}
Flow Range (Full Scale Capacity)
3 sccm - 2500 lpm
{98B3B921-99AA-44E8-A95A-B2B32C0443EE}
Accuracy
± 0.6% of SP
{5926F692-5544-4A73-B01B-FAD04C270B7C}
Max Pressure
4500 psig
{3E832D90-A88A-4F1F-A695-A417A3E4EFFA}
Temperature
65oC
{936BB9F8-90E4-435D-8978-2534DBC0C8A8}
Output Type
Analog & Digital
  • For processes sensitive to moisture or oxygen
  • High purity flow path minimizes process contamination, enhances yield
  • Ultra-fast response time
{4B16B008-8B97-4936-913D-8968C3C47CB6}
Fluid Type
Gas
{1978A936-D391-47B0-9DD8-781560753BC4}
Flow Range (Full Scale Capacity)
3 sccm - 300 slpm
{A1450FED-5D83-44A4-9A36-DFB8499490BF}
Accuracy
SP ±1%
{34182DC6-D16A-437F-8683-DC2BFDE0E72E}
Max Pressure
150 psig
{6CC6EE13-EA1C-4D01-A096-93E9C793477A}
Temperature
50oC
{3EB75C7E-C7A1-457B-917D-CFC92B29932C}
Output Type
Analog & Digital
  • Highest operating temperature
  • High accuracy and repeatability
  • Ultra-high purity construction
{8D4C6DBA-EEEC-42DC-B954-E469E88923F8}
Fluid Type
Gas, Vapor
{4D034DB9-C880-4604-94EE-751326470C7D}
Flow Range (Full Scale Capacity)

50 sccm - 100 slm

{966F2288-31A6-4FB2-A59C-8E96D9889977}
Accuracy
±1% of SP
{14561F9A-1D52-4C64-B9CF-2F16451C4D6F}
Max Pressure
500 psia
{9617F8FC-A12B-4574-BA30-40FE1069F592}
Temperature
150oC
{9286B4B5-6608-448F-93A4-ECC445D47307}
Output Type
Analog & Digital
  • Highest accuracy for very low-flow processes
  • Multi-variable device provides flow, density and temperature
  • Devices for both liquid and gas applications
{0066CFC8-4EBE-4499-BFC4-5164CC1552EE}
Fluid Type
Gas, Liquids
{E6685411-A2AE-4ADC-AAFC-9CC17AADC3A8}
Flow Range (Full Scale Capacity)

10 - 27,000 gram/hr

{8879CE76-43E5-45EF-8C91-9839B6C97A42}
Accuracy
0.2% - 0.5% of Rate
{296161DC-4196-49EA-AED5-6154A2E563A1}
Max Pressure
4500 psi
{35273F94-A47A-4174-AD0C-694431AD18A5}
Temperature
60oC
{76912886-3FBE-4651-B213-E0787EE15BF8}
Output Type
Analog & Digital